Skip to content
Sandweiler, Luxembourg
Call
WhatsApp
HomeComparisonsLPU 42 vs LPU 67 Thermo
VS
COMPARISON - HÖRMANN MODELS

LPU 42
vs
LPU 67 Thermo

7 min read 8 technical criteria Hörmann datasheets 2026 Updated 2026

The Hörmann internal duel. LPU 42 is the residential market standard. LPU 67 Thermo takes insulation further (67 mm thermally broken panels, U = 1.0 W/m²K installed door versus 1.3 W/m²K) for a noticeable premium (on quote). Is it really justified for your garage? This comparison analyses 8 technical criteria with Hörmann catalogue figures.

Verdict summary
LPU 42
2/8
CRITERIA WON
LPU 67
3/8
CRITERIA WON
Hörmann LPU 42 sectional panel anthracite 42 mm
OPTION A

Hörmann LPU 42

The residential standard

Hörmann LPU 67 Thermo sectional door, 67 mm thermally broken panels
OPTION B

Hörmann LPU 67 Thermo

Enhanced 67 mm insulation

147
Google reviews
20+
Years of expertise
4.7/5
Google rating
5 yrs
Hörmann operator warranty (max.)
10 yrs
Hörmann door warranty (max.)
Authorised Hörmann installer
Roma doors
CE-marked doors · EN 13241 installation
Professional liability insurance
01
01 - OVERVIEW

Both panels in numbers

LPU 42 and LPU 67 Thermo share the same general Hörmann structure: double-wall steel, polyurethane foam. LPU 67 Thermo adds 25 mm of thickness, thermally broken panels and a double lip seal between panels: insulation improves markedly, and the premium is far from trivial.

Hörmann LPU 42 sectional panel anthracite 42 mm
Residential standard
01

Hörmann LPU 42

The residential standard

Thickness
42 mm
U-value
1.3 W/m²K (installed door)
Panel weight
Lighter (42 mm)
Installed price
On quote
Hörmann LPU 67 Thermo sectional door, 67 mm thermally broken panels
Enhanced insulation
02

Hörmann LPU 67 Thermo

Enhanced 67 mm insulation

Thickness
67 mm
U-value
1.0 W/m²K (installed door)
Panel weight
Heavier (67 mm)
Installed price
On quote
02
02 - COMPARISON

8 technical criteria

Each criterion is evaluated on the 2026 Hörmann datasheets and our site experience in Luxembourg, where we install both models.

U insulation coefficient
LPU 67
LPU 42

1.3 W/m²K installed door (panel 0.53 W/m²K), 1.2 W/m²K with the optional ThermoFrame. 42 mm double-wall steel panel.

LPU 67

1.0 W/m²K installed door (panel 0.31 W/m²K), 0.91 W/m²K with the optional ThermoFrame - about 23% better than LPU 42. 67 mm thermally broken panels.

Installed price Luxembourg
Tie
LPU 42

Free quote on request. Standard Silkgrain finish, motor, installation and removal itemised in the quote. Market reference, clearly cheaper than the LPU 67 Thermo.

LPU 67

Free quote on request. Noticeable premium over the LPU 42 at equivalent dimensions. Gap only justified on specific use cases.

Weight and frame requirements
LPU 42
LPU 42

Lighter 42 mm panel: standard torsion springs and operator, simple installation in most situations.

LPU 67

Heavier 67 mm panel: Hörmann sizes the torsion springs accordingly. It is still driven by the same ProMatic 4 / SupraMatic 4 operators, with no HT operator required.

Required lintel drop
Tie
LPU 42

Minimum headroom (powered door): 115 mm with Z and L track (100 mm manual), 210 mm with N track. Larger values with ThermoFrame or CR2.

LPU 67

Same base values as LPU 42: 115 mm with Z and L track (100 mm manual), 210 mm with N track. The CR2 equipment, standard on LPU 67, may increase the required headroom.

Annual thermal profitability
LPU 67
LPU 42

Clear heating saving compared with an uninsulated door, especially on a heated attached garage.

LPU 67

Door heat losses roughly a quarter lower than LPU 42 (1.0 versus 1.3 W/m²K installed door). The gain only becomes noticeable if the garage is heated.

Finishes & decors
LPU 42
LPU 42

7 surfaces (Woodgrain, Slategrain, Silkgrain, Sandgrain, Planar, Decograin in 6 designs, Duragrain in 30 designs), approx. 200 RAL colours. Full catalogue.

LPU 67

Narrower choice: Silkgrain surface (smooth, many colours including approx. 200 RAL) or Decograin in 3 designs (Titan Metallic, Golden Oak, Dark Oak), M or L ribs. No Woodgrain, Sandgrain, Planar or Duragrain.

Security & anti-burglary
LPU 67
LPU 42

Anti-lift protection via the operator, fall protection, obstacle detection. CR2 (RC2) burglar-resistant equipment available as an option.

LPU 67

Same safety systems as LPU 42, plus CR2 (RC2) burglar-resistant equipment as standard.

Required operator
Tie
LPU 42

ProMatic 4 or SupraMatic E4 (650 N, 800 N peak) for doors up to 5,500 mm wide and 13.75 m². Beyond that: SupraMatic P4 or H4.

LPU 67

Same ProMatic 4 / SupraMatic 4 operators (K, M, L rails); no HT operator required. For a large door: SupraMatic P4 (up to 15 m²) or H4 (up to 18 m²).

03
03 - PROS & CONS

Pros & cons

Concrete strengths and weaknesses of each Hörmann panel, as our technicians see them on both ranges in Luxembourg.

LPU 42

Pros
  • De facto residential market standard
  • Good insulation: U = 1.3 W/m²K installed door (1.2 with optional ThermoFrame)
  • Installed price clearly below LPU 67 Thermo (free quote)
  • Wider size range: up to 6,000 × 3,000 mm
  • Can be driven by ProMatic 4 or SupraMatic 4 depending on door size
  • Full finish catalogue (7 surfaces, approx. 200 RAL, Duragrain in 30 designs)
Cons
  • Less insulation than LPU 67 Thermo (1.3 versus 1.0 W/m²K installed door)
  • CR2 burglar-resistant equipment only as an option (standard on LPU 67)
  • Not an option if you are seeking absolute maximum insulation

LPU 67 Thermo

Pros
  • Insulation U = 1.0 W/m²K installed door (0.91 with optional ThermoFrame), panel 0.31 W/m²K
  • 67 mm thermally broken panels, double lip seal between panels
  • CR2 (RC2) burglar-resistant equipment as standard
  • EN 13241 classes: wind load class 3, air and water tightness class 3
  • Real thermal gain mainly in a heated garage or one adjoining heated rooms
Cons
  • Noticeable premium on full installation (free quote)
  • Heavier panel and width limited to 5,000 mm (versus 6,000 mm for LPU 42)
  • Limited finishes: Silkgrain and Decograin (3 designs) only
  • Long thermal payback on an unheated garage
04
04 - PROFILES

Which for your garage?

The LPU 67 Thermo premium is only justified in 3 to 4 specific cases. Here are the 6 typical profiles - 4 that should stay on LPU 42 and 2 where LPU 67 is genuinely justified.

Passive or very low-energy house

You are building or renovating a passive or very low-energy house. The garage door becomes a weak point of the envelope. LPU 67 Thermo is Hörmann's best-insulated sectional door (1.0 W/m²K installed door, 0.91 with ThermoFrame): have the value validated by your design office.

→ LPU 67 Thermo
Standard new build

You are in a standard new build with an unheated garage. LPU 42 (1.3 W/m²K installed door, 1.2 with ThermoFrame) offers good insulation. Paying for LPU 67 is rarely justified.

→ LPU 42
Heated garage / thermostated workshop

You heat your garage like a living space (workshop, wine cellar, gym). LPU 67's insulation gain pays off over the long term.

→ LPU 67 Thermo
Retrofit on existing frame

You are replacing an existing door in an opening with tight dimensions (width, headroom). LPU 42 offers more track types, sizes (up to 6,000 mm wide) and finishes: often the simplest technical choice.

→ LPU 42
Standard family home

You have a classic residential home with integral garage. LPU 42 is technically sufficient. Keep the price difference to invest elsewhere (SupraMatic motor, Duragrain finish).

→ LPU 42
Cautious budget replacement

You replace an old non-insulated door. Moving to a LPU 42 sectional already represents a huge thermal leap. LPU 67 Thermo is overkill on this profile.

→ LPU 42 or RenoMatic
05
VERDICT

Our recommendation:
a tie on score, LPU 42 by default depending on use

Across 8 criteria, LPU 67 Thermo wins 3, LPU 42 2, with 3 ties (including price, on quote for both): the gap on score is small. The choice therefore depends on use: the LPU 42 covers most residential needs in Luxembourg at a clearly lower price, and its U-value of 1.3 W/m²K installed door (1.2 with ThermoFrame) is enough for most garages.

LPU 67 Thermo is only really justified in 2 specific cases: passive or very low-energy house (where every envelope element counts) and intensively heated garage (workshop, wine cellar, home gym). Outside these cases, the premium takes a very long time to pay back. Our advice: LPU 42 by default, LPU 67 only if your architect or your use explicitly calls for it.

Available nowFree, fast quoteSince 2007Authorised Hörmann installer
Final scores
U insulation coefficient
LPU 67
Installed price Luxembourg
Tie
Weight and frame requirements
LPU 42
Required lintel drop
Tie
Annual thermal profitability
LPU 67
Finishes & decors
LPU 42
Security & anti-burglary
LPU 67
Required operator
Tie
06
FAQ
FAQ

Frequently asked questions

Answers to our customers' most common questions.

Have another question? Contact us
Authorised Hörmann installer
Official installer

As an installed door, LPU 42 reaches U = 1.3 W/m²K (panel 0.53) and LPU 67 Thermo U = 1.0 W/m²K (panel 0.31); with the optional ThermoFrame, 1.2 and 0.91 W/m²K. The complete door therefore loses about 23% less heat with LPU 67 Thermo. The gap is perceptible on the heating bill only if the garage itself is heated or communicates with heated rooms.

FL
YOUR PROJECT

LPU 42 or LPU 67 for your garage?

Our technicians analyse your project (new build, retrofit, garage heating level, possible thermal certification) and honestly tell you whether the LPU 67 Thermo premium is justified in your case. Free visit across Luxembourg, free and fast quote.

Free visit
Free, fast quote
No obligation
Authorised Hörmann installer

Customise your preferences

Choose which cookies you accept, category by category. Necessary cookies are always active: without them, the website does not work properly. All others are only set with your consent. Cookie policy

Always active

Essential for the website to work: they remember your cookie choice. They are not used for audience measurement or advertising.

Help us understand how the website is used (page views, journeys, requests sent) so we can improve it. Statistics are aggregated.

Let us measure how well our ads work (knowing that a request follows an ad) and show you our ads on these platforms. When you send a request, your contact details (email, phone number, first and last name, town) may be shared with them in encrypted (hashed) form to link the request to the ad.