INDUSTRY - FIRE CURTAIN

FlexFire fabric
fire curtain Hörmann

E30 to EI2 30 CE EN 16034 Gravity Fail Safe Up to 5,500 mm

FlexFire is a fabric fire curtain designed to disappear into an overhead housing and deploy automatically in case of fire. Glass fibre or technical E-Glass fabric, classifications from E30 to EI2 30 per EN 13501-2, mandatory CE marking EN 16034 since 2019. Gravity-driven closing without power, guide rails only 115 mm wide, widths up to 5,500 mm - the invisible fire compartmentation solution for public buildings, logistics and underground car parks.

EI2 30full insulation
5.5 mmax width
115 mmguide rails
Hörmann FlexFire textile fire curtain
KEY BENEFITS

Invisible fire compartmentation

FlexFire replaces steel fire doors for large openings: zero floor footprint, no visual obstruction during normal operation, and certified automatic deployment on fire alarm. A fire safety engineering solution for buildings where aesthetics, flow and surface area matter.

Invisible when open

The fabric curtain rolls up into a compact housing that integrates into suspended ceilings. Zero visual obstruction, no floor obstacle, no interference with pedestrian or vehicle flows. The only compartmentation device that respects the architecture of open halls, shopping galleries and entrance lobbies.

Large openings up to 5,500 mm

Width up to 5,500 mm and height up to 5,310 mm in a single unit - where a steel fire door would force heavy partitioning. Ideal to compartment logistics halls, shopping galleries or evacuation corridors without architectural break.

Certified EI2 30 insulation

FlexFire EI2 30 delivers 30 minutes of integrity and full thermal insulation (unexposed face temperature limited to +140 K average / +180 K peak), compliant with EN 13501-2. Versions E30 to E120 and EW30 to EW90 available depending on the regulatory requirement of your compartment.

EN 16034 compliance - CE marking

Since November 2019, harmonised standard EN 16034 makes CE marking mandatory for any fire-resistant closure sold in the European Union. FlexFire is tested and certified to EN 16034 and EN 13241 - declaration of performance supplied with every installation.

Gravity Fail Safe closing

FlexFire closes under its own weight, without electrical power, with integrated speed regulation. In the event of power failure, fire alarm or malfunction, closing is guaranteed. Magnetic contact integrated in the guide rails for position detection.

Flexible & modular compartmentation

Guide rails only 115 mm wide, wall or ceiling mounting, invisible integration in suspended ceilings. FlexFire adapts to existing architectural constraints - including retrofitting public buildings or warehouses where adding a steel fire door would be impossible.

TECHNICAL SPECIFICATIONS

Technical data FlexFire

Data extracted from the Hörmann FlexFire fabric fire curtain catalogue. Values certified per EN 13501-2 (classification), EN 16034 (product) and EN 13241 (door performance).

Fire resistance classes
E30 - flame barrier 30 minLight grey glass fabric / aluminised PU
E60 - flame barrier 60 minLight grey glass fabric / aluminised PU
E90 - flame barrier 90 minLight grey glass fabric / aluminised PU
E120 - flame barrier 120 minLight grey glass fabric / aluminised PU
EW30 / EW60 - radiationAnthracite fabric, double-sided silicone
EW90 - radiation 90 minBlack E-Glass + IsoTherm-Flies Intum EI
EI2 30 - full insulation+140 K average / +180 K peak
Standard referenceEN 13501-2
Dimensions
Min width1,000 mm
Max width (E, EW, EI2 30)5,500 mm
Max width (EW90)3,500 mm
Max height (E to EW60)5,310 mm
Max height (EI2 30)5,005 mm
Max height (EW90)2,500 mm
Guide rail width115 mm
Operation & safety
Closing modeGravity (Gravity Fail Safe)
Power supplyNot required for closing
Position detectionIntegrated magnetic contacts
DriveIntegrated tubular motor
Drive EW90 / EI2 30External Anflansch drive
Speed regulationIntegrated - EN 16034 compliant
Certification & compliance
Fire classificationEN 13501-2
Harmonised product standardEN 16034 (CE mandatory)
Industrial doorsEN 13241
Smoke detectorsH-RM-4070 - EN 54-7
Heat detectorsH-TM-4070 - EN 54-7
Optical-acoustic alarmDIN EN 14600
VARIANTS

Four configurations FlexFire

The FlexFire range comes in 4 Hörmann catalogue variants - each matching a specific fire resistance class and adapted fabric construction. Fermelux guides you in selecting the right classification according to your applicable fire safety regulation.

FlexFire fire curtain E30 to E120 - flame barrier glass fabric
Flame barrier

FlexFire E30 to E120

(FlexFire E30 bis E120)

Flame barrier curtain with light grey glass fabric, V4A thread and aluminised PU coating (690 g/m², 0.54 mm). Classifications E30, E60, E90 and E120 depending on required integrity duration. The most compact configuration, ideal for standard compartmentation in logistics and public buildings.

  • › Light grey glass fabric
  • › Aluminised PU 690 g/m²
  • › Width up to 5,500 mm
  • › Height up to 5,310 mm
FlexFire fire curtain EW30 EW60 - radiation reduction
Radiation

FlexFire EW30 / EW60

(FlexFire EW30 / EW60)

Thermal radiation reduction for 30 or 60 minutes with anthracite glass fabric, V4A thread and double-sided silicone coating (1,750 g/m², 1.50 mm). Recommended for evacuation corridors where thermal radiation must be limited on the escape route side.

  • › Anthracite silicone fabric
  • › 1,750 g/m² - 1.50 mm
  • › Width up to 5,500 mm
  • › Height up to 5,310 mm
FlexFire fire curtain EW90 - E-Glass high performance
EW90

FlexFire EW90

(FlexFire EW90)

High-performance version in black E-Glass with V4A thread and IsoTherm-Flies with Intum EI coating (5,500 g/m², 11 mm). Thermal radiation reduction for 90 minutes. Thicker construction: max width 3,500 mm, max height 2,500 mm.

  • › E-Glass + Intum EI
  • › 5,500 g/m² - 11 mm
  • › Max width 3,500 mm
  • › Max height 2,500 mm
FlexFire fire curtain EI2 30 - full thermal insulation
Full insulation

FlexFire EI2 30

(FlexFire EI2 30)

Full insulation for 30 minutes: integrity + thermal insulation, unexposed face temperature limited to +140 K average and +180 K peak. Same construction as EW90. This is the required configuration for compartments needing certified thermal insulation (evacuation, hospital rooms, accommodation).

  • › +140 K avg / +180 K peak
  • › E-Glass + Intum EI
  • › Width up to 5,500 mm
  • › Height up to 5,005 mm
DRIVE & FIRE CONTROL

Drives & control panels Hörmann FlexControl

FlexFire features a silent tubular motor in the shaft (or an Anflansch drive for the heavy EW90 / EI2 30 versions) with pre-wired cabling. Closing is controlled by a dedicated Hörmann hold-open system, connected to the building's detectors and fire alarm.

Compatible drives

Integrated tubular motor

Silent motor integrated into the winding shaft with pre-wired cabling. Standard for all E, EW30 and EW60 versions. No work on the housing on site: everything is pre-wired ex Hörmann factory.

  • › Integrated in shaft
  • › Factory pre-wired
  • › Silent
  • › Standard E / EW30 / EW60

Anflansch drive (EW90 / EI2 30)

External flanged drive for the heavy EW90 and EI2 30 fabrics (5,500 g/m², 11 mm). Designed to handle the thickest fabric constructions while guaranteeing the closing speed regulation required by EN 16034.

  • › External drive
  • › Heavy versions
  • › EW90 / EI2 30
  • › Speed regulation

FSA-FLEXControl panel

DIBt-approved Hörmann hold-open system, without inverter. Controls opening and closing of FlexFire from the building's detectors and fire alarm. Reference for classic public and industrial installations.

  • › DIBt-approved
  • › Without inverter
  • › EN 54 compatible
  • › FSA standard

FAA-Plus panel

High-end hold-open system with integrated backup battery power supply. Guarantees control of the fire curtain even during prolonged mains failure - mandatory for sites with strict continuity requirements (hospitals, data centers, industry).

  • › Backup battery
  • › Secured supply
  • › Hospitals / data centers
  • › DIBt-approved

FSA-FLEXeco

Economical version of the hold-open panel, without DIBt approval. Intended for installations where DIBt approval is not required by the inspection body. FLEXeco Plus variant available with backup battery.

  • › Economical version
  • › Without DIBt
  • › FLEXeco Plus with battery
  • › EN 54 compatible

Optical-acoustic alarm

Integrated audible and visual alarm compliant with DIN EN 14600, triggered when the curtain closes to warn occupants. Mandatory for fire curtains installed in pedestrian traffic areas (galleries, corridors, exits).

  • › Audible signal
  • › DIN EN 14600
  • › Optical + acoustic
  • › Recommended option
Fire detection & equipment
H-RM-4070 smoke detector
EN 54-7 certified optical smoke detector, compatible with FSA-FLEXControl panel. Ceiling installation above the curtain.
H-TM-4070 heat detector
EN 54-7 certified heat detector, for zones where smoke detection is unsuitable (kitchens, dusty workshops).
Integrated magnetic contact
Position detection in the guide rails, invisible, with no visible wired loop. Status reporting to the panel.
DIN EN 14600 alarm
Audible and visual signalling when the curtain closes - mandatory in pedestrian evacuation zones.
Wall or ceiling mounting
Housing installable surface-mounted on wall or integrated in a suspended ceiling depending on the architectural configuration.
RAL customisation
Guide rails and housing painted in RAL colour of choice to blend with the interior finishes of public buildings, shopping galleries and entrance halls.
FREE, FAST FIRE SAFETY STUDY

A FlexFire fire curtain projectin Luxembourg?

Installing a certified fire curtain requires fire safety engineering expertise. Fermelux handles the study, sizing, integration with your fire alarm system and commissioning with compliance report. Free on-site survey, free, fast quote.

STANDARDS & COMPLIANCE

Fire safety CE-certified

Since November 2019, placing a fire-resistant closure on the European market requires CE marking per EN 16034. Every FlexFire is supplied with declaration of performance, commissioning report and fire classification test report.

EN 13501-2 - Fire classification

European classification of fire resistance for construction products (E, EW, EI). Basis for all FlexFire classifications E30 to EI2 30. Fire test report supplied with every installation.

EN 13501-2:2016+A1:2019

EN 16034 - Fire-resistant closures (CE mandatory)

European harmonised product standard governing doors, gates and windows with fire resistance characteristics. CE marking mandatory since 1 November 2019 for any fire closure sold in the EU.

EN 16034:2014

EN 13241 - Industrial, commercial and garage doors

Harmonised standard covering general safety and performance requirements for motorised closures. Applicable to FlexFire in addition to EN 16034.

EN 13241:2003+A2:2016

EN 54-7 - Smoke detectors

Standard for point optical smoke detectors. H-RM-4070 detectors and H-TM-4070 heat detectors compatible with FlexFire are certified to EN 54-7.

EN 54-7:2018
USE CASES

6 sectors where FlexFire excels

FlexFire is the fire compartmentation solution for buildings where a steel fire door would be disproportionate, unsightly or impossible to integrate. Here are the 6 sectors where we install it most often in Luxembourg.

Logistics & open-space warehouses

Compartmentation of a storage hall exceeding the maximum compartment surface imposed by the fire safety regulation - without partitioning the space in normal operation.

FlexFire E60 or E90 + FSA-FLEXControl

Underground & silo car parks

Separation of underground car park compartments in accordance with fire compartmentation rules. Invisible integration in concrete slabs.

FlexFire E90 or E120 + H-TM-4070 heat detectors

Shopping centres & public buildings

Shopping galleries, entrance halls, evacuation corridors in public buildings. Invisible compartmentation that preserves the customer experience.

FlexFire EW60 or EI2 30 + DIN EN 14600 alarm

Hospitals & care facilities

Separation of care units, protection of rooms and corridors. Full EI2 30 thermal insulation is essential to preserve patient evacuation routes.

FlexFire EI2 30 + FAA-Plus panel with battery

Industry & regulated facilities

Facilities regulated for environmental protection: compartmentation of fire-risk zones in workshops, process rooms and combustible storage areas.

FlexFire E60 to E120 + H-TM-4070 heat detectors

Public building / heritage renovation

Bringing existing public buildings up to code where adding a steel fire door would be impossible (lintel, aesthetics, flow). FlexFire integrates in suspended ceilings without structural work.

FlexFire EW60 or EI2 30 + ceiling mounting
OPTIONS & ACCESSORIES

Customisation FlexFire catalogue

FlexFire can be adapted to the constraints of your fire alarm system and your architecture. Here are the most requested Hörmann catalogue options on our fire safety projects in Luxembourg.

FSA-FLEXControl panel
DIBt-approved hold-open system, without inverter. Reference for classic public building installations.
FAA-Plus panel
High-end panel with integrated backup battery power supply - hospitals, data centers, sites with strict continuity requirements.
FSA-FLEXeco
Economical version of the control panel, without DIBt approval, for installations where it is not required.
FSA-FLEXeco Plus
FLEXeco with backup battery - good cost/continuity trade-off for secondary public buildings.
H-RM-4070 smoke detector
Point optical detector certified EN 54-7, connected to the FlexControl panel.
H-TM-4070 heat detector
EN 54-7 heat detector, for zones unsuitable for smoke detection (kitchens, workshops).
Optical-acoustic alarm
DIN EN 14600 alarm, mandatory in pedestrian evacuation zones when the curtain closes.
RAL colour of choice
Customisation of guide rails and housing in RAL for architectural integration.
Wall mounting
Surface-mounted housing on masonry, for installations without suspended ceiling.
Integrated ceiling mounting
Invisible integration in a suspended ceiling - the most aesthetic configuration.
INDICATIVE BUDGET

FlexFire fire curtain budget

Each fire curtain is priced on request (free quote), including installation, fire alarm system wiring and commissioning. FlexFire is a premium fire safety product whose budget varies with fire class, dimensions and control panel.

Flame barrier

FlexFire E30 / E60 + FSA-FLEXeco

Price on request

Flame barrier curtain for standard compartmentation in logistics or secondary public buildings. FLEXeco control without DIBt, H-RM-4070 smoke detection, commissioning included.

  • Light grey glass fabric + aluminised PU
  • Integrated tubular motor
  • FSA-FLEXeco panel
  • 1 H-RM-4070 smoke detector
  • Installation and commissioning
  • CE EN 16034 declaration of performance
Standard public

FlexFire E60 / EW60 + FSA-FLEXControl

Price on request

Most common configuration in Luxembourg public buildings and logistics: DIBt-approved control, smoke detection, optical-acoustic alarm, integration into existing fire alarm system.

  • Anthracite double-sided silicone fabric
  • FSA-FLEXControl panel (DIBt)
  • 2 H-RM-4070 detectors
  • Optical-acoustic alarm
  • Building fire alarm system integration
  • Commissioning report
Premium insulation

FlexFire EI2 30 + FAA-Plus

Price on request

Full EI2 30 insulation with FAA-Plus panel and backup battery power supply. For hospitals, data centers and sites with strict continuity and evacuation requirements.

  • E-Glass fabric + IsoTherm-Flies Intum EI
  • External Anflansch drive
  • FAA-Plus panel + battery
  • Smoke + heat detectors
  • DIN EN 14600 alarm
  • Fire alarm system integration + compliance report

The exact budget depends on the required fire class, dimensions, control panel and fire alarm system integration. Free on-site survey in Luxembourg, free, fast detailed study by a fire safety specialist technician.

Request a fire safety study
147
Google reviews
20+
Years of expertise
4.7/5
Google rating
5 yrs
Hörmann operator warranty (max.)
10 yrs
Hörmann door warranty (max.)
Authorised Hörmann installer
Roma doors
CE-marked doors · EN 13241 installation
Professional liability insurance
FAQ
FAQ

Frequently asked questions

Answers to our customers' most common questions.

Have another question? Contact us
Authorised Hörmann installer
Official installer

They are the three EN 13501-2 classification levels: E (integrity) = the curtain remains tight against flames and hot gases for the stated duration, with no guarantee on radiation. EW (radiation) = in addition to integrity, thermal radiation on the unexposed face is limited to a maximum of 15 kW/m². EI2 (insulation) = in addition to E, the average unexposed face temperature is limited to +140 K and the peak to +180 K. EI2 30 is the required configuration to protect an escape route or a sensitive compartment (hospital, accommodation), whereas E and EW are sufficient for classic logistics compartmentation.

FL
CERTIFIED FIRE CURTAIN INSTALLATION

Invisible fire compartmentationby Hörmann

Founded in 2007, Fermelux is an authorised Hörmann installer in Luxembourg, with a dedicated fire safety team trained on FlexControl and FAA-Plus panels. Fire safety study, sizing, fire alarm system integration, compliance report. Free on-site survey, free, fast quote.

Authorised Hörmann installer
Fire safety specialist
CE EN 16034 compliance
Commissioning report
Dedicated maintenance contract
+352 35 53 78
No obligation Fast, free quote Free site visit

Customise your preferences

Choose which cookies you accept, category by category. Necessary cookies are always active: without them, the website does not work properly. All others are only set with your consent. Cookie policy

Always active

Essential for the website to work: they remember your cookie choice. They are not used for audience measurement or advertising.

Help us understand how the website is used (page views, journeys, requests sent) so we can improve it. Statistics are aggregated.

Let us measure how well our ads work (knowing that a request follows an ad) and show you our ads on these platforms. When you send a request, your contact details (email, phone number, first and last name, town) may be shared with them in encrypted (hashed) form to link the request to the ad.