FlexFire fabric
fire curtain Hörmann
FlexFire is a fabric fire curtain designed to disappear into an overhead housing and deploy automatically in case of fire. Glass fibre or technical E-Glass fabric, classifications from E30 to EI2 30 per EN 13501-2, mandatory CE marking EN 16034 since 2019. Gravity-driven closing without power, guide rails only 115 mm wide, widths up to 5,500 mm - the invisible fire compartmentation solution for public buildings, logistics and underground car parks.

Invisible fire compartmentation
FlexFire replaces steel fire doors for large openings: zero floor footprint, no visual obstruction during normal operation, and certified automatic deployment on fire alarm. A fire safety engineering solution for buildings where aesthetics, flow and surface area matter.
Invisible when open
The fabric curtain rolls up into a compact housing that integrates into suspended ceilings. Zero visual obstruction, no floor obstacle, no interference with pedestrian or vehicle flows. The only compartmentation device that respects the architecture of open halls, shopping galleries and entrance lobbies.
Large openings up to 5,500 mm
Width up to 5,500 mm and height up to 5,310 mm in a single unit - where a steel fire door would force heavy partitioning. Ideal to compartment logistics halls, shopping galleries or evacuation corridors without architectural break.
Certified EI2 30 insulation
FlexFire EI2 30 delivers 30 minutes of integrity and full thermal insulation (unexposed face temperature limited to +140 K average / +180 K peak), compliant with EN 13501-2. Versions E30 to E120 and EW30 to EW90 available depending on the regulatory requirement of your compartment.
EN 16034 compliance - CE marking
Since November 2019, harmonised standard EN 16034 makes CE marking mandatory for any fire-resistant closure sold in the European Union. FlexFire is tested and certified to EN 16034 and EN 13241 - declaration of performance supplied with every installation.
Gravity Fail Safe closing
FlexFire closes under its own weight, without electrical power, with integrated speed regulation. In the event of power failure, fire alarm or malfunction, closing is guaranteed. Magnetic contact integrated in the guide rails for position detection.
Flexible & modular compartmentation
Guide rails only 115 mm wide, wall or ceiling mounting, invisible integration in suspended ceilings. FlexFire adapts to existing architectural constraints - including retrofitting public buildings or warehouses where adding a steel fire door would be impossible.
Technical data FlexFire
Data extracted from the Hörmann FlexFire fabric fire curtain catalogue. Values certified per EN 13501-2 (classification), EN 16034 (product) and EN 13241 (door performance).
Four configurations FlexFire
The FlexFire range comes in 4 Hörmann catalogue variants - each matching a specific fire resistance class and adapted fabric construction. Fermelux guides you in selecting the right classification according to your applicable fire safety regulation.

FlexFire E30 to E120
(FlexFire E30 bis E120)Flame barrier curtain with light grey glass fabric, V4A thread and aluminised PU coating (690 g/m², 0.54 mm). Classifications E30, E60, E90 and E120 depending on required integrity duration. The most compact configuration, ideal for standard compartmentation in logistics and public buildings.
- › Light grey glass fabric
- › Aluminised PU 690 g/m²
- › Width up to 5,500 mm
- › Height up to 5,310 mm

FlexFire EW30 / EW60
(FlexFire EW30 / EW60)Thermal radiation reduction for 30 or 60 minutes with anthracite glass fabric, V4A thread and double-sided silicone coating (1,750 g/m², 1.50 mm). Recommended for evacuation corridors where thermal radiation must be limited on the escape route side.
- › Anthracite silicone fabric
- › 1,750 g/m² - 1.50 mm
- › Width up to 5,500 mm
- › Height up to 5,310 mm

FlexFire EW90
(FlexFire EW90)High-performance version in black E-Glass with V4A thread and IsoTherm-Flies with Intum EI coating (5,500 g/m², 11 mm). Thermal radiation reduction for 90 minutes. Thicker construction: max width 3,500 mm, max height 2,500 mm.
- › E-Glass + Intum EI
- › 5,500 g/m² - 11 mm
- › Max width 3,500 mm
- › Max height 2,500 mm

FlexFire EI2 30
(FlexFire EI2 30)Full insulation for 30 minutes: integrity + thermal insulation, unexposed face temperature limited to +140 K average and +180 K peak. Same construction as EW90. This is the required configuration for compartments needing certified thermal insulation (evacuation, hospital rooms, accommodation).
- › +140 K avg / +180 K peak
- › E-Glass + Intum EI
- › Width up to 5,500 mm
- › Height up to 5,005 mm
Drives & control panels Hörmann FlexControl
FlexFire features a silent tubular motor in the shaft (or an Anflansch drive for the heavy EW90 / EI2 30 versions) with pre-wired cabling. Closing is controlled by a dedicated Hörmann hold-open system, connected to the building's detectors and fire alarm.
Integrated tubular motor
Silent motor integrated into the winding shaft with pre-wired cabling. Standard for all E, EW30 and EW60 versions. No work on the housing on site: everything is pre-wired ex Hörmann factory.
- › Integrated in shaft
- › Factory pre-wired
- › Silent
- › Standard E / EW30 / EW60
Anflansch drive (EW90 / EI2 30)
External flanged drive for the heavy EW90 and EI2 30 fabrics (5,500 g/m², 11 mm). Designed to handle the thickest fabric constructions while guaranteeing the closing speed regulation required by EN 16034.
- › External drive
- › Heavy versions
- › EW90 / EI2 30
- › Speed regulation
FSA-FLEXControl panel
DIBt-approved Hörmann hold-open system, without inverter. Controls opening and closing of FlexFire from the building's detectors and fire alarm. Reference for classic public and industrial installations.
- › DIBt-approved
- › Without inverter
- › EN 54 compatible
- › FSA standard
FAA-Plus panel
High-end hold-open system with integrated backup battery power supply. Guarantees control of the fire curtain even during prolonged mains failure - mandatory for sites with strict continuity requirements (hospitals, data centers, industry).
- › Backup battery
- › Secured supply
- › Hospitals / data centers
- › DIBt-approved
FSA-FLEXeco
Economical version of the hold-open panel, without DIBt approval. Intended for installations where DIBt approval is not required by the inspection body. FLEXeco Plus variant available with backup battery.
- › Economical version
- › Without DIBt
- › FLEXeco Plus with battery
- › EN 54 compatible
Optical-acoustic alarm
Integrated audible and visual alarm compliant with DIN EN 14600, triggered when the curtain closes to warn occupants. Mandatory for fire curtains installed in pedestrian traffic areas (galleries, corridors, exits).
- › Audible signal
- › DIN EN 14600
- › Optical + acoustic
- › Recommended option
A FlexFire fire curtain projectin Luxembourg?
Installing a certified fire curtain requires fire safety engineering expertise. Fermelux handles the study, sizing, integration with your fire alarm system and commissioning with compliance report. Free on-site survey, free, fast quote.
Fire safety CE-certified
Since November 2019, placing a fire-resistant closure on the European market requires CE marking per EN 16034. Every FlexFire is supplied with declaration of performance, commissioning report and fire classification test report.
EN 13501-2 - Fire classification
European classification of fire resistance for construction products (E, EW, EI). Basis for all FlexFire classifications E30 to EI2 30. Fire test report supplied with every installation.
EN 13501-2:2016+A1:2019EN 16034 - Fire-resistant closures (CE mandatory)
European harmonised product standard governing doors, gates and windows with fire resistance characteristics. CE marking mandatory since 1 November 2019 for any fire closure sold in the EU.
EN 16034:2014EN 13241 - Industrial, commercial and garage doors
Harmonised standard covering general safety and performance requirements for motorised closures. Applicable to FlexFire in addition to EN 16034.
EN 13241:2003+A2:2016EN 54-7 - Smoke detectors
Standard for point optical smoke detectors. H-RM-4070 detectors and H-TM-4070 heat detectors compatible with FlexFire are certified to EN 54-7.
EN 54-7:20186 sectors where FlexFire excels
FlexFire is the fire compartmentation solution for buildings where a steel fire door would be disproportionate, unsightly or impossible to integrate. Here are the 6 sectors where we install it most often in Luxembourg.
Logistics & open-space warehouses
Compartmentation of a storage hall exceeding the maximum compartment surface imposed by the fire safety regulation - without partitioning the space in normal operation.
Underground & silo car parks
Separation of underground car park compartments in accordance with fire compartmentation rules. Invisible integration in concrete slabs.
Shopping centres & public buildings
Shopping galleries, entrance halls, evacuation corridors in public buildings. Invisible compartmentation that preserves the customer experience.
Hospitals & care facilities
Separation of care units, protection of rooms and corridors. Full EI2 30 thermal insulation is essential to preserve patient evacuation routes.
Industry & regulated facilities
Facilities regulated for environmental protection: compartmentation of fire-risk zones in workshops, process rooms and combustible storage areas.
Public building / heritage renovation
Bringing existing public buildings up to code where adding a steel fire door would be impossible (lintel, aesthetics, flow). FlexFire integrates in suspended ceilings without structural work.
Customisation FlexFire catalogue
FlexFire can be adapted to the constraints of your fire alarm system and your architecture. Here are the most requested Hörmann catalogue options on our fire safety projects in Luxembourg.
FlexFire fire curtain budget
Each fire curtain is priced on request (free quote), including installation, fire alarm system wiring and commissioning. FlexFire is a premium fire safety product whose budget varies with fire class, dimensions and control panel.
FlexFire E30 / E60 + FSA-FLEXeco
Flame barrier curtain for standard compartmentation in logistics or secondary public buildings. FLEXeco control without DIBt, H-RM-4070 smoke detection, commissioning included.
- Light grey glass fabric + aluminised PU
- Integrated tubular motor
- FSA-FLEXeco panel
- 1 H-RM-4070 smoke detector
- Installation and commissioning
- CE EN 16034 declaration of performance
FlexFire E60 / EW60 + FSA-FLEXControl
Most common configuration in Luxembourg public buildings and logistics: DIBt-approved control, smoke detection, optical-acoustic alarm, integration into existing fire alarm system.
- Anthracite double-sided silicone fabric
- FSA-FLEXControl panel (DIBt)
- 2 H-RM-4070 detectors
- Optical-acoustic alarm
- Building fire alarm system integration
- Commissioning report
FlexFire EI2 30 + FAA-Plus
Full EI2 30 insulation with FAA-Plus panel and backup battery power supply. For hospitals, data centers and sites with strict continuity and evacuation requirements.
- E-Glass fabric + IsoTherm-Flies Intum EI
- External Anflansch drive
- FAA-Plus panel + battery
- Smoke + heat detectors
- DIN EN 14600 alarm
- Fire alarm system integration + compliance report
The exact budget depends on the required fire class, dimensions, control panel and fire alarm system integration. Free on-site survey in Luxembourg, free, fast detailed study by a fire safety specialist technician.
Request a fire safety studyFrequently asked questions
Answers to our customers' most common questions.
Invisible fire compartmentationby Hörmann
Founded in 2007, Fermelux is an authorised Hörmann installer in Luxembourg, with a dedicated fire safety team trained on FlexControl and FAA-Plus panels. Fire safety study, sizing, fire alarm system integration, compliance report. Free on-site survey, free, fast quote.